Kaba IC8 OC8

This Kaba IC8 OC8 optional feature is implemented when a solution requires more binary inputs or relay outputs than available on the door unit. When using these modules, a single access control reader allows users to selectively open specific access points (up to 24), eliminating fingerprint keys or Wiegand readers at every access point. This configuration is ideal in retail, healthcare, and banking facilities where users need to open a specific display case, cabinet, drawer, safe, or server cabinet. This system protects valuable assets and data; eliminates keys and cards; and reduces equipment requirements, installation time and costs.
Features
- Eight additional inputs for connection of insulated switches
- Eight additional relay outputs
- Supports up to three input/output modules on each controller
- DIN rail mounting
- Direct plug to controller with plug connector
OC8
Outputs…………………………………..8 relay outputs, Changeover contact, max. voltage 34 VDC, max. current 2 A at 30 VDC, cycles of operation at 30 VDC/1 A typically 500,000 (VdS 2358 requirement is 200,000), cycles of operation at VDC/2 A typically 100,000, LED status display
Mechanical……………………………..DIN rail mounted with removable screw terminations of field hardware, mounts in standard third-party locking enclosures
Connections……………………………All connections involve screw/plug terminals. Maximum terminal load : 5 A
Power………………………………………Provided by the door unit. 10 to 34 VDC. Current consumption max. 250 mA at 10 VDC
Dimensions……………………………..2.75 x 3.9 x 1.77 in (70 x 99 x 45 mm)
Ambient Conditions……………….Operating temperature: 32 to 122 °F (0 to 50 °C), Storage temperature: -4 to 149 °F (-20 to 65 °C), Relative humidity: 0 to 95% non-condensing
Protection Type………………………IP40
Flammability Class…………………HB (UL94)
IC8
Inputs………………………………………8 binary inputs, with internal power supply and common ground for connection of floating contacts, LED status display
Mechanical……………………………..DIN rail mounted with removable screw terminations of field hardware, mounts in standard third-party locking enclosures
Connections……………………………All connections involve screw/plug terminals
Power………………………………………Provided by the door unit. 5 VDC, current consumption max. 200 mA
Dimensions……………………………..2.75 x 3.9 x 1.77 in (70 x 99 x 45 mm)
Ambient Conditions……………….Operating temperature: 32 to 122 °F (0 to 50 °C), Storage temperature: -4 to 149 °F (-20 to 65 °C),Relative humidity: 0 to 95% non-condensing
Protection Type………………………IP40
Flammability Class…………………HB (UL94)